FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource StructureDefinition/FHIR Server from package nictiz.fhir.nl.stu3.zib2015#1.0.0 (140 ms)

Package nictiz.fhir.nl.stu3.zib2015
Type StructureDefinition
Id Id
FHIR Version R3
Source https://simplifier.net/resolve?scope=nictiz.fhir.nl.stu3.zib2015@1.0.0&canonical=http://nictiz.nl/fhir/StructureDefinition/bp
Url http://nictiz.nl/fhir/StructureDefinition/bp
Version 1.0
Status retired
Date 2016-03-25
Name Vital Signs Profile
Title VitalSigns BloodPressure
Experimental False
Realm nl
Description FHIR Blood Pressure Profile - Copied FHIR Vital Signs Profile to remove .component.value quantity type constrain. More information can be found in the GForge ticket #13796.
Copyright CC0
Type Observation
Kind resource

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
http://nictiz.nl/fhir/StructureDefinition/zib-VitalSigns VitalSigns


Narrative

Note: links and images are rebased to the (stated) source

to do

Source

{
  "resourceType" : "StructureDefinition",
  "id" : "bp",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">to do</div>"
  },
  "extension" : [
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-summary",
      "valueMarkdown" : "####Complete Summary of the Mandatory Requirements\r\r1. One code in `Observation.code` which must have\r - a fixed `Observation.code.coding.system`=**'http ://loinc.org'**\r - a fixed `Observation.code.coding.code`= **85354-9'**\r - Other additional codes are allowed - e.g. more specific LOINC\r Codes, SNOMED CT concepts, system specific codes. All codes\r SHALL have an system value\r2. One `Observation.component.code` which must have\r - a fixed `Observation.component.code.coding.system`=**'http://loinc.org'**\r - fixed `Observation.component.code.coding.code`= **'8480-6'**\r - Other additional codes are allowed - e.g. more specific LOINC\r Codes, SNOMED CT concepts, system specific codes. All codes\r SHALL have an system value\r3. One `Observation.component.code` which must have\r - a fixed `Observation.component.code.coding.system`=**'http://loinc.org'**\r - fixed `Observation.component.code.coding.code`= **'8462-4'**\r - Other additional codes are allowed - e.g. more specific LOINC\r Codes, SNOMED CT concepts, system specific codes. All codes\r SHALL have an system value\r4. fixed`Observation.component.valueQuantity.code` = **'mm[Hg]'**"
    }
  ],
  "url" : "http://nictiz.nl/fhir/StructureDefinition/bp",
  "version" : "1.0",
  "name" : "Vital Signs Profile",
  "title" : "VitalSigns BloodPressure",
  "status" : "retired",
  "experimental" : false,
  "date" : "2016-03-25",
  "publisher" : "Health Level Seven International (Orders and Observations Workgroup)",
  "contact" : [
    {
      "name" : "Nictiz",
      "telecom" : [
        {
          "system" : "email",
          "value" : "info@nictiz.nl",
          "use" : "work"
        }
      ]
    }
  ],
  "description" : "FHIR Blood Pressure Profile - Copied FHIR Vital Signs Profile to remove .component.value quantity type constrain. More information can be found in the GForge ticket #13796.",
  "copyright" : "CC0",
  "fhirVersion" : "3.0.1",
  "mapping" : [
    {
      "identity" : "hcim-bloodpressure-v1.2-2015EN",
      "uri" : "https://zibs.nl/wiki/BloodPressure-v1.2(2015EN)",
      "name" : "HCIM BloodPressure-v1.2(2015EN)"
    }
  ],
  "kind" : "resource",
  "abstract" : false,
  "type" : "Observation",
  "baseDefinition" : "http://nictiz.nl/fhir/StructureDefinition/zib-VitalSigns",
  "derivation" : "constraint",
  "differential" : {
    "element" : [
      {
        "id" : "Observation",
        "path" : "Observation",
        "short" : "FHIR Blood Pressure Profile",
        "definition" : "This profile defines how to represent Blood Pressure observations in FHIR using a standard LOINC code and UCUM units of measure. This is a grouping structure. It has no value in Observation.valueQuantity but contains at least one component (systolic and/or diastolic).",
        "alias" : [
          "FHIR Bloeddruk-profiel"
        ],
        "min" : 0,
        "max" : "*",
        "mapping" : [
          {
            "identity" : "hcim-bloodpressure-v1.2-2015EN",
            "map" : "NL-CM:12.4.1"
          }
        ]
      },
      {
        "id" : "Observation.code",
        "path" : "Observation.code",
        "comment" : "additional codes that translate or map to this code are allowed. For example a more granular LOINC code or code that is used locally in a system."
      },
      {
        "id" : "Observation.code.coding",
        "path" : "Observation.code.coding",
        "slicing" : {
          "discriminator" : [
            {
              "type" : "value",
              "path" : "code"
            }
          ],
          "ordered" : false,
          "rules" : "open"
        }
      },
      {
        "id" : "Observation.code.coding:BPCode",
        "path" : "Observation.code.coding",
        "sliceName" : "BPCode"
      },
      {
        "id" : "Observation.code.coding:BPCode.system",
        "path" : "Observation.code.coding.system",
        "type" : [
          {
            "code" : "uri"
          }
        ],
        "fixedUri" : "http://loinc.org"
      },
      {
        "id" : "Observation.code.coding:BPCode.code",
        "path" : "Observation.code.coding.code",
        "type" : [
          {
            "code" : "code"
          }
        ],
        "fixedCode" : "85354-9"
      },
      {
        "id" : "Observation.valueQuantity",
        "path" : "Observation.valueQuantity",
        "min" : 0,
        "max" : "0"
      },
      {
        "id" : "Observation.component",
        "path" : "Observation.component",
        "slicing" : {
          "discriminator" : [
            {
              "type" : "value",
              "path" : "code.coding.code"
            }
          ],
          "ordered" : false,
          "rules" : "open"
        }
      },
      {
        "id" : "Observation.component:SystolicBP",
        "path" : "Observation.component",
        "sliceName" : "SystolicBP"
      },
      {
        "id" : "Observation.component:SystolicBP.code",
        "path" : "Observation.component.code",
        "comment" : "additional codes that translate or map to this code are allowed. For example a more granular LOINC code or code that is used locally in a system."
      },
      {
        "id" : "Observation.component:SystolicBP.code.coding",
        "path" : "Observation.component.code.coding",
        "slicing" : {
          "discriminator" : [
            {
              "type" : "value",
              "path" : "code"
            }
          ],
          "ordered" : false,
          "rules" : "open"
        }
      },
      {
        "id" : "Observation.component:SystolicBP.code.coding:SBPCode",
        "path" : "Observation.component.code.coding",
        "sliceName" : "SBPCode",
        "definition" : "Systolic Blood Pressure."
      },
      {
        "id" : "Observation.component:SystolicBP.code.coding:SBPCode.system",
        "path" : "Observation.component.code.coding.system",
        "type" : [
          {
            "code" : "uri"
          }
        ],
        "fixedUri" : "http://loinc.org"
      },
      {
        "id" : "Observation.component:SystolicBP.code.coding:SBPCode.code",
        "path" : "Observation.component.code.coding.code",
        "type" : [
          {
            "code" : "code"
          }
        ],
        "fixedCode" : "8480-6"
      },
      {
        "id" : "Observation.component:SystolicBP.valueQuantity",
        "path" : "Observation.component.valueQuantity",
        "short" : "SystolicBloodPressure",
        "alias" : [
          "SystolischeBloeddruk"
        ],
        "type" : [
          {
            "code" : "Quantity"
          }
        ],
        "mapping" : [
          {
            "identity" : "hcim-bloodpressure-v1.2-2015EN",
            "map" : "NL-CM:12.4.2"
          }
        ]
      },
      {
        "id" : "Observation.component:SystolicBP.valueQuantity.code",
        "path" : "Observation.component.valueQuantity.code",
        "type" : [
          {
            "code" : "code"
          }
        ],
        "fixedCode" : "mm[Hg]"
      },
      {
        "id" : "Observation.component:DiastolicBP",
        "path" : "Observation.component",
        "sliceName" : "DiastolicBP"
      },
      {
        "id" : "Observation.component:DiastolicBP.code",
        "path" : "Observation.component.code",
        "comment" : "additional codes that translate or map to this code are allowed. For example a more granular LOINC code or code that is used locally in a system."
      },
      {
        "id" : "Observation.component:DiastolicBP.code.coding",
        "path" : "Observation.component.code.coding",
        "slicing" : {
          "discriminator" : [
            {
              "type" : "value",
              "path" : "code"
            }
          ],
          "ordered" : false,
          "rules" : "open"
        }
      },
      {
        "id" : "Observation.component:DiastolicBP.code.coding:DBPCode",
        "path" : "Observation.component.code.coding",
        "sliceName" : "DBPCode",
        "definition" : "Diastolic Blood Pressure."
      },
      {
        "id" : "Observation.component:DiastolicBP.code.coding:DBPCode.system",
        "path" : "Observation.component.code.coding.system",
        "type" : [
          {
            "code" : "uri"
          }
        ],
        "fixedUri" : "http://loinc.org"
      },
      {
        "id" : "Observation.component:DiastolicBP.code.coding:DBPCode.code",
        "path" : "Observation.component.code.coding.code",
        "type" : [
          {
            "code" : "code"
          }
        ],
        "fixedCode" : "8462-4"
      },
      {
        "id" : "Observation.component:DiastolicBP.valueQuantity",
        "path" : "Observation.component.valueQuantity",
        "short" : "DiastolicBloodPressure",
        "alias" : [
          "DiastolischeBloeddruk"
        ],
        "type" : [
          {
            "code" : "Quantity"
          }
        ],
        "mapping" : [
          {
            "identity" : "hcim-bloodpressure-v1.2-2015EN",
            "map" : "NL-CM:12.4.3"
          }
        ]
      },
      {
        "id" : "Observation.component:DiastolicBP.valueQuantity.code",
        "path" : "Observation.component.valueQuantity.code",
        "type" : [
          {
            "code" : "code"
          }
        ],
        "fixedCode" : "mm[Hg]"
      }
    ]
  }
}

XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.