Package | nictiz.fhir.nl.stu3.zib2015 |
Type | StructureDefinition |
Id | Id |
FHIR Version | R3 |
Source | https://simplifier.net/resolve?scope=nictiz.fhir.nl.stu3.zib2015@1.0.0&canonical=http://nictiz.nl/fhir/StructureDefinition/bp |
Url | http://nictiz.nl/fhir/StructureDefinition/bp |
Version | 1.0 |
Status | retired |
Date | 2016-03-25 |
Name | Vital Signs Profile |
Title | VitalSigns BloodPressure |
Experimental | False |
Realm | nl |
Description | FHIR Blood Pressure Profile - Copied FHIR Vital Signs Profile to remove .component.value quantity type constrain. More information can be found in the GForge ticket #13796. |
Copyright | CC0 |
Type | Observation |
Kind | resource |
No resources found
StructureDefinition | |
http://nictiz.nl/fhir/StructureDefinition/zib-VitalSigns | VitalSigns |
Note: links and images are rebased to the (stated) source
{
"resourceType" : "StructureDefinition",
"id" : "bp",
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">to do</div>"
},
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-summary",
"valueMarkdown" : "####Complete Summary of the Mandatory Requirements\r\r1. One code in `Observation.code` which must have\r - a fixed `Observation.code.coding.system`=**'http ://loinc.org'**\r - a fixed `Observation.code.coding.code`= **85354-9'**\r - Other additional codes are allowed - e.g. more specific LOINC\r Codes, SNOMED CT concepts, system specific codes. All codes\r SHALL have an system value\r2. One `Observation.component.code` which must have\r - a fixed `Observation.component.code.coding.system`=**'http://loinc.org'**\r - fixed `Observation.component.code.coding.code`= **'8480-6'**\r - Other additional codes are allowed - e.g. more specific LOINC\r Codes, SNOMED CT concepts, system specific codes. All codes\r SHALL have an system value\r3. One `Observation.component.code` which must have\r - a fixed `Observation.component.code.coding.system`=**'http://loinc.org'**\r - fixed `Observation.component.code.coding.code`= **'8462-4'**\r - Other additional codes are allowed - e.g. more specific LOINC\r Codes, SNOMED CT concepts, system specific codes. All codes\r SHALL have an system value\r4. fixed`Observation.component.valueQuantity.code` = **'mm[Hg]'**"
}
],
"url" : "http://nictiz.nl/fhir/StructureDefinition/bp",
"version" : "1.0",
"name" : "Vital Signs Profile",
"title" : "VitalSigns BloodPressure",
"status" : "retired",
"experimental" : false,
"date" : "2016-03-25",
"publisher" : "Health Level Seven International (Orders and Observations Workgroup)",
"contact" : [
{
"name" : "Nictiz",
"telecom" : [
{
"system" : "email",
"value" : "info@nictiz.nl",
"use" : "work"
}
]
}
],
"description" : "FHIR Blood Pressure Profile - Copied FHIR Vital Signs Profile to remove .component.value quantity type constrain. More information can be found in the GForge ticket #13796.",
"copyright" : "CC0",
"fhirVersion" : "3.0.1",
"mapping" : [
{
"identity" : "hcim-bloodpressure-v1.2-2015EN",
"uri" : "https://zibs.nl/wiki/BloodPressure-v1.2(2015EN)",
"name" : "HCIM BloodPressure-v1.2(2015EN)"
}
],
"kind" : "resource",
"abstract" : false,
"type" : "Observation",
"baseDefinition" : "http://nictiz.nl/fhir/StructureDefinition/zib-VitalSigns",
"derivation" : "constraint",
"differential" : {
"element" : [
{
"id" : "Observation",
"path" : "Observation",
"short" : "FHIR Blood Pressure Profile",
"definition" : "This profile defines how to represent Blood Pressure observations in FHIR using a standard LOINC code and UCUM units of measure. This is a grouping structure. It has no value in Observation.valueQuantity but contains at least one component (systolic and/or diastolic).",
"alias" : [
"FHIR Bloeddruk-profiel"
],
"min" : 0,
"max" : "*",
"mapping" : [
{
"identity" : "hcim-bloodpressure-v1.2-2015EN",
"map" : "NL-CM:12.4.1"
}
]
},
{
"id" : "Observation.code",
"path" : "Observation.code",
"comment" : "additional codes that translate or map to this code are allowed. For example a more granular LOINC code or code that is used locally in a system."
},
{
"id" : "Observation.code.coding",
"path" : "Observation.code.coding",
"slicing" : {
"discriminator" : [
{
"type" : "value",
"path" : "code"
}
],
"ordered" : false,
"rules" : "open"
}
},
{
"id" : "Observation.code.coding:BPCode",
"path" : "Observation.code.coding",
"sliceName" : "BPCode"
},
{
"id" : "Observation.code.coding:BPCode.system",
"path" : "Observation.code.coding.system",
"type" : [
{
"code" : "uri"
}
],
"fixedUri" : "http://loinc.org"
},
{
"id" : "Observation.code.coding:BPCode.code",
"path" : "Observation.code.coding.code",
"type" : [
{
"code" : "code"
}
],
"fixedCode" : "85354-9"
},
{
"id" : "Observation.valueQuantity",
"path" : "Observation.valueQuantity",
"min" : 0,
"max" : "0"
},
{
"id" : "Observation.component",
"path" : "Observation.component",
"slicing" : {
"discriminator" : [
{
"type" : "value",
"path" : "code.coding.code"
}
],
"ordered" : false,
"rules" : "open"
}
},
{
"id" : "Observation.component:SystolicBP",
"path" : "Observation.component",
"sliceName" : "SystolicBP"
},
{
"id" : "Observation.component:SystolicBP.code",
"path" : "Observation.component.code",
"comment" : "additional codes that translate or map to this code are allowed. For example a more granular LOINC code or code that is used locally in a system."
},
{
"id" : "Observation.component:SystolicBP.code.coding",
"path" : "Observation.component.code.coding",
"slicing" : {
"discriminator" : [
{
"type" : "value",
"path" : "code"
}
],
"ordered" : false,
"rules" : "open"
}
},
{
"id" : "Observation.component:SystolicBP.code.coding:SBPCode",
"path" : "Observation.component.code.coding",
"sliceName" : "SBPCode",
"definition" : "Systolic Blood Pressure."
},
{
"id" : "Observation.component:SystolicBP.code.coding:SBPCode.system",
"path" : "Observation.component.code.coding.system",
"type" : [
{
"code" : "uri"
}
],
"fixedUri" : "http://loinc.org"
},
{
"id" : "Observation.component:SystolicBP.code.coding:SBPCode.code",
"path" : "Observation.component.code.coding.code",
"type" : [
{
"code" : "code"
}
],
"fixedCode" : "8480-6"
},
{
"id" : "Observation.component:SystolicBP.valueQuantity",
"path" : "Observation.component.valueQuantity",
"short" : "SystolicBloodPressure",
"alias" : [
"SystolischeBloeddruk"
],
"type" : [
{
"code" : "Quantity"
}
],
"mapping" : [
{
"identity" : "hcim-bloodpressure-v1.2-2015EN",
"map" : "NL-CM:12.4.2"
}
]
},
{
"id" : "Observation.component:SystolicBP.valueQuantity.code",
"path" : "Observation.component.valueQuantity.code",
"type" : [
{
"code" : "code"
}
],
"fixedCode" : "mm[Hg]"
},
{
"id" : "Observation.component:DiastolicBP",
"path" : "Observation.component",
"sliceName" : "DiastolicBP"
},
{
"id" : "Observation.component:DiastolicBP.code",
"path" : "Observation.component.code",
"comment" : "additional codes that translate or map to this code are allowed. For example a more granular LOINC code or code that is used locally in a system."
},
{
"id" : "Observation.component:DiastolicBP.code.coding",
"path" : "Observation.component.code.coding",
"slicing" : {
"discriminator" : [
{
"type" : "value",
"path" : "code"
}
],
"ordered" : false,
"rules" : "open"
}
},
{
"id" : "Observation.component:DiastolicBP.code.coding:DBPCode",
"path" : "Observation.component.code.coding",
"sliceName" : "DBPCode",
"definition" : "Diastolic Blood Pressure."
},
{
"id" : "Observation.component:DiastolicBP.code.coding:DBPCode.system",
"path" : "Observation.component.code.coding.system",
"type" : [
{
"code" : "uri"
}
],
"fixedUri" : "http://loinc.org"
},
{
"id" : "Observation.component:DiastolicBP.code.coding:DBPCode.code",
"path" : "Observation.component.code.coding.code",
"type" : [
{
"code" : "code"
}
],
"fixedCode" : "8462-4"
},
{
"id" : "Observation.component:DiastolicBP.valueQuantity",
"path" : "Observation.component.valueQuantity",
"short" : "DiastolicBloodPressure",
"alias" : [
"DiastolischeBloeddruk"
],
"type" : [
{
"code" : "Quantity"
}
],
"mapping" : [
{
"identity" : "hcim-bloodpressure-v1.2-2015EN",
"map" : "NL-CM:12.4.3"
}
]
},
{
"id" : "Observation.component:DiastolicBP.valueQuantity.code",
"path" : "Observation.component.valueQuantity.code",
"type" : [
{
"code" : "code"
}
],
"fixedCode" : "mm[Hg]"
}
]
}
}
XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.